Specifications
For AC/DC Clamp On Meter Model :M9912
Range
|
Resolution
|
Accuracy
|
3V
|
1mV
|
±0.8%
of rdg ±1 digit
|
30V
|
10mV
|
300V
|
0.1V
|
1000V
|
1V
|
±1.0%
of rdg ± 2 digits
|
Input
Impedence:10M
AC
VOLTAGE
Range
|
Resolution
|
Accuracy
|
3V
|
1mV
|
±0.1%
of rdg ±5 digit
|
30V
|
10mV
|
300V
|
0.1V
|
1000V
|
1V
|
±1.2%
of rdg ± 5 digits
|
Input
Impedance:10M
Frequency
range:40Hz to 200Hz
Response:
Average responding, calibrated in rms. of a sine wave.
AC
CURRENT
Range |
Resolution |
ACCURACY |
300A |
0.1A |
<600A
±2.0% of rdg ±10 digit
>600A
±3.0% of rdg ±10 digit |
1000A |
1.0A |
Overload Protection:1200A
for 60 seconds max. Freq.range:50Hz to 60Hz
DC CURRENT
Range |
Resolution |
ACCURACY |
300A |
0.1A |
<600A
±2.0% of rdg ± 5 digit
>600A
±3.0% of rdg ± 5 digit |
1000A |
1 A |
Overload Protection:1200A
for 60 seconds max.
RESISTANCE
Maximum
Open Circuit Voltage 1.3V
Overload
Protection:250VDC or RMS AC for all ranges.
FREQUENCY
Range |
Resolution |
ACCURACY |
30KHz |
10Hz |
±2.0%
of rdg ± 10 digit |
Sensitivity
:200mV rms, Input Limit:250V AC
AUDIBLE
CONTINUITY AND DIODE
Range |
Description |
Buzz |
If
continuity exists (about less than 18),built
in buzzer will sound |
Diode |
Show
the approx forward voltage of the diode. |
|